20060243 38 A CSR - Sheet - A801 - ROOF DETAILS
New roof membrane new lead drain pan flashing 2'-0" from centerline of drain in all directions. extend min. 1" into drain bowl existing roof drain to electrical feed in conduit from closest panel (provide new 15a breaker) 1-1/2" drain thru wall 1" rpz above ceiling frost free hose bibb ... Access This Document
COMMUNITY DEVELOPMENT, BUILDING AND SAFETY
Within this document include the structural and electrical elements of the 2010 California Residential Code note that the conduit is to kept 18” below the roof surface Identify and show method of sealing the roof penetrations. (e.g. flashing, ... View Document
Roof Curbs, Extensions And Equipment Supports - Greenheck
Roof Curbs, ExtensionsPage Header and Equipment Supports Prefabricated roof curbs reduce installation time and costs by ensuring compatibility between the fan, curb ... Retrieve Document
26 05 33 Conduit And Fittings - Christenson Corporation
A. Provide complete grounded conduit systems for all electrical conductors. A. Use prefabricated pipe flashing of ultra-violet resistant EDPM rubber G. EMT shall not be installed on the underside of metal roof decking. H. RMC conduit shall be used on roofs with appropriate ... Read Full Source
CONSULTANTS BANK OF AMERICA BUILDING REROOFING LEON COUNTY ...
Liquid applied reinforced roof flashing system with minimum (dry) mils thickness requirements. raise existing electrical conduit, associated piping, condensate lines and rooftop equipment and curbs, install pressure treated 2x wood ... Read More
Galvanization - Wikipedia, The Free Encyclopedia
Rusted corrugated steel roof. but it may vary by region due to impurities in the water supply and the proximity of electrical grids for which interior piping acts as a pathway but galvanized steel pipes are still used in outdoor applications requiring steel's superior mechanical strength. ... Read Article
In-Line Blowers & Flat Roof Blowers - AJ Madison
Horizontal dimension of the curb after the flashing work should be 1/2” smaller than the bottom frame of the blower housing. After the curb is built, cut a circle into the roof deck, 1/2 Drill a 1/2” hole for the electrical conduit. Have a licensed electrician pull the electrical ... Visit Document
LEAD FREE PIPE FLASHINGS - Welcome To Direct Metals Inc.
LEAD FREE PIPE FLASHINGS The new solution for flashing electrical mast connections on shingle roofing. FOR ELECTRICAL CONDUIT PENETRATIONS IN SHINGLE ROOFING DMI ROUND RETROFIT FLASHINGS - (Zipperboot) Designed to water proof electrical conduit, masts, service ... Read Here
ROOF ASSESSMENT - US Inspect
One HVAC unit condensate drain line is discharging directly onto the conduit penetration through the roof. A large area of stains is present at the rear by the electrical roof. The seams at the left wall flashing area are not sealed. ... Visit Document
Index Of Standard Details
Adhered EPDM Roof Electrical Conduit Penetration - Ballasted EPDM Roof Gas Relief Vent Pipe Flashing - Adhered EPDM Roof Weatherhead Mast - Ballasted EPDM Roof 076000 Flashing and Sheet Metal 078100 Applied Fireproofing 078400 Firestopping ... Document Retrieval
ELMDOR/STONEMAN 1100-4 Series - BuildSite LLC
ELMDOR/STONEMAN 1100-4 Series FLASHING assemblies are recommended for flashing all roof penetrations from 1" SPS through 12" on each roof penetration Elmdor/Stoneman #1100-5 Lead Flashing Pipe and Electrical Rigid Conduit; Schedules 40 & 80 ABS & ... View Full Source
Electromagnetic Shielding - Wikipedia, The Free Encyclopedia
One example is a shielded cable, which has electromagnetic shielding in the form of a wire mesh surrounding an inner core conductor. The shielding impedes the escape of any signal from the core conductor, and also prevents signals from being added to the core conductor. ... Read Article
Troubleshooting Wet Basement Problems - DIY Home Repair
Wet Basement Problems. Improper roof downspout drainage or site drainage against foundation wall eroded soil under foundation and caused settlement crack. Shockingly Easy Electrical Repairs; Get Comfortable With These Heating and Cooling Tips; ... Read Article
Orchard Commercial Project 7700 2013 Annual Roof Survey
Support sleeper redesign sp relieved pressure on through-roof conduit penetrations. Orchard Commercial 4 March 2013 R5 = Roof Hatch Repair R6 = Skylight Flashing Repair R7 = Repair or Replace Skylight Lens R44 = Open Electrical Conduit/Junction Box ... Fetch Full Source
Profile Direct Drive Centrifugal Power Roof Ventilators shall be Carnes Company Model VELK. CONSTRUCTION FEATURES 3 Speed Motor Integral Mounting Brackets and conduit will be in accordance with electrical specifications and local The roof flashing is shown installed over a standard ... Visit Document
HOW TO INSTALL A 200 AMP ELECTRICAL SERVICE
HOW TO INSTALL A 200 AMP ELECTRICAL SERVICE This will describe the most common type or conduit feed (underground). Place the roof flashing over top end of mast, properly fit upper edge under roofing materials, ... Read Here
Wall Penetration Flashing Kits - Polyguard Products, Inc.
WALL PENETRATION FLASHING KIT US Patent # 7,568,314B2 1. DESCRIPTION A Polyguard Wall Penetration Flashing Kit (WPF) 12. Install a surface mounted electrical box with the backside of the box stopped out against the outer edge of Part 5. ... View Doc
How To flash Around An Existing electric Service Mast Pipe On ...
Re roofing around an existing service head. This gizmo costs more than the cheap ones but works well and should never leak since such a great design. I do not sell these but used one on my existing roof. I wanted a design that had no seam to fail; or one that uses goop to seal. This ... View Video
CONSULTANTS LEON COUNTY COURTHOUSE ANNEX REROOFING ...
Florida fire prevention code, (ffpc) 2007 edition national electrical code, (nec) remove existing roof materials including single ply roof and flashing membrane, recovery board, gravel surface bur, vent thru roof electrical conduit overflow scupper new overflow scupper pitch pocket ... Doc Viewer
Roofing And Penetrations 2009 Version 1 With AmendmentsJL
Wall penetrations shall be set out so as to finish clear above the line of any perimeter roof flashing. Individual The university will not accept fluted flexible electrical conduit with this type of flashing as water travels Roofing_and_Penetrations_2009_version_1_with_amendmentsJL ... Fetch Content
ASI Products
ASI Products Waterproofing Storm Collar Applications E.P.D.M. Roof Flashing Storm Collars waterproof multiple pipe penetrations with our patented rubber umbrellas. roof top electrical service. ... View Full Source
EPDM ROOFING HANDBOOK - Conservation Technology
To assure proper bonding and flashing, apply EPDM only Cut the EPDM roof sheet at a 45° angle as sewer vents and electrical service entry conduit. Two sizes are available: a small boot for 1/2”, 1”, 2”, and 3” ... Fetch Full Source
DUIT Electrical/Utility PRICE LIST - Weld-On
Electrical conduit or any non-pressure PVC applications through 6”. Complies with NEMA and UL specifications. 3 year shelf life 12737 12738 Qt Pt 12 12 28 14 0.67 0.36 Electrical mast roof flashing Constructed of durable EPDM rubber, split-boot, ... Retrieve Content